Rx: 70Gy/35fx to PTV70, also PTV63 and PTV56 (simultaneous integrated boost)

2017 QADS / ProKnow Plan Study

http://medicalaffairs.varian.com/image/badge_award-128_clean_red90.png

3:44 IMRT treatment field delivery time (estimated)

Beams
DVH
Metrics

Name (ID): 2017 QADS Head Neck PS, head and neck (2017 QADS PS HN)
Plan or PlanSum ID: 144.49

Structure IDStructure CodePatient StructureDVH ObjectiveEvaluatorVariationPriorityMetAchieved
PTV_70PTV_70V70Gy[%]>=9590Variation94.36 %
PTV_70PTV_70V73.5Gy[%]<=010Goal0.00 %
PTV_70PTV_70D0.03cc[Gy]<71.377Variation72.670 Gy
CTV_70CTV_70V70Gy[%]>=9995Goal99.79 %
PTV63 - PTV70PTV63 - PTV70V63Gy[%]>=9590Goal95.98 %
PTV63 - PTV70PTV63 - PTV70V66.15Gy[%]<=2060Variation31.19 %
CTV63 - CTV70CTV63 - CTV70V63Gy[%]>=9995Goal99.75 %
PTV56 - PTV63PTV56 - PTV63V56Gy[%]>=9590Goal95.76 %
PTV56 - PTV63PTV56 - PTV63V58.8Gy[%]<3060Goal24.18 %
CTV56 - CTV63CTV56 - CTV63V56Gy[%]>=9995Goal99.56 %
SPINAL_CORDSPINAL_CORDD0.03cc[Gy]<47.99948Goal47.074 Gy
BRAINSTEMBRAINSTEMD0.03cc[Gy]<51.99952Goal50.644 Gy
RT COCHLEART COCHLEAD0.03cc[Gy]<=3545Goal24.183 Gy
LT COCHLEALT COCHLEAD0.03cc[Gy]<=3545Goal28.486 Gy
LIPSLIPSV30Gy[%]<=2040Goal15.52 %
RT_PAROTIDRT_PAROTIDMean[Gy]<2430Goal23.782 Gy
MANDIBLE1MANDIBLE1V70Gy[%]<=1025Goal9.16 %
LARYNXLARYNXMean[Gy]<4050Goal38.958 Gy
Post Neck1Post Neck1V35Gy[%]<=1030Goal9.14 %
Technical Plan Comments

This plan was created with the inital 1cm effective leaf size configuration.  Nine (9) static gantry positions were selected such that the beams follow the inverted V target shape in the transverse view.  Uniquie colimator rotations were selected from the beams eye view.

Comparative Plan Quality
Links

Review 3rd party software generated full treatment plan report

PDF

                              

Download full DICOM CT, struct, plan and dose file         

ZIP        

Any reference to a "plan study" are simply what the organizers call each case and may not be a "study" in the FDA sense as they may not have been published in a peer reviewed journal.
Varian does not provide medical advice and these are illustrative examples only.
Leading plans by expert planner. Your results may vary.

FOR EDUCATIONAL AND SCIENTIFIC EXCHANGE ONLY – NOT FOR SALES OR PROMOTIONAL USE.

 