VMAT

Beams
DVH
Simple DVH Metrics

Name (ID): 2014 AAPM SBRT Lung, 2014 AAPM SBRT Lung (2014 AAPM SBRT Lung)
Plan or PlanSum ID: SBRT RA

Structure ID Structure Code Patient Structure DVH Objective Evaluator Variation Priority Met Achieved
PTV   PTV V60.0Gy[%] >=95 90   Goal 98.00 %
PTV   PTV V54.0Gy[%] >=100 99   Goal 100.00 %
PTV   PTV D0.03cc[Gy] >=66.666 100   Goal 82.360 Gy
ITV   itv1 V60.0Gy[%] >=100 99   Goal 100.00 %
2CM GRADIENT   2CM GRADIENT D0.03cc[Gy] <=30.1 35   Goal 29.225 Gy
LUNG_TOTAL   TOTAL LUNG V20.0Gy[%] <=5 10   Goal 3.09 %
LUNG_R   LUNG_R V5.0Gy[%] <=1 5   Goal 0.28 %
SPINAL_CORD   SPINAL CORD D0.03cc[Gy] <18     Goal 8.627 Gy
ESOPHAGUS   ESOPHAGUS D0.03cc[Gy] <=10 15   Goal 8.367 Gy
HEART   HEART D0.03cc[Gy] <=15 20   Goal 13.915 Gy
SKIN   SKIN D0.03cc[Gy] <=15 20   Goal 13.229 Gy
RIB   RIB D0.03cc[Gy] <=32 40   Goal 29.549 Gy
AIRWAY   AIRWAY D0.03cc[Gy] <=15 25   Goal 11.290 Gy
ScoreCard Metrics
Technical Plan Comments

This plan was one of three plans to score a perfect 150/150 in the AAPM 2014 SBRTlung Plan Challenge.  The only MLC based plans able to achieve this score were Varian HDMLC plans.

Comparative Plan Quality
Links

3rd party software plan report

PDF

  Dosimetric ScoreCard

JSON

DICOM patient export        

ZIP        

Any reference to a "plan study" are simply what the organizers call each case and may not be a "study" in the FDA sense as they may not have been published in a peer reviewed journal.
Varian does not provide medical advice and these are illustrative examples only.
Leading plans by expert planner. Your results may vary.

FOR EDUCATIONAL AND SCIENTIFIC EXCHANGE ONLY – NOT FOR SALES OR PROMOTIONAL USE.