VMAT

Rx: 40Gy/5fx to prostate gland and 36.25Gy to PTV (simultaneous integrated boost)

2016 AAMD RSS ProKnow Plan Study

http://medicalaffairs.varian.com/image/badge_award-128_clean_blue95.png

 

Beams
DVH
Simple DVH Metrics

Name (ID): ProstateSBRT, ProstateSBRT (2016AAMD_RSS_SBRT_PROSTAT), (0066)
Plan or PlanSum ID: Plan10x146.66

Structure ID Structure Code Patient Structure DVH Objective Evaluator Variation Priority Met Achieved
PTV   PTV_P_P V36.25Gy[%] >=95 90   Goal 99.37 %
PROSTATE   Prostate_P1_P V40.0Gy[%] >=100 90   Variation 99.25 %
PTV   PTV_P_P D0.03cc[Gy] >=36.25 29   Goal 48.236 Gy
RECTUM   Rectum_P1_P V36.0Gy[cc] <=0 2   Variation 0.05 cc
BLADDER   Bladder_P1_P V37.0Gy[cc] <=0 5   Variation 0.07 cc
RECTUM   Rectum_P1_P D40.0%[Gy] <=10 20   Variation 10.381 Gy
URETHRA   Urethra_P_P D20.0%[Gy] <=40 44   Variation 40.160 Gy
BOWEL   Bowel_P_P D1.0cc[Gy] <=0 30   Variation 1.575 Gy
PENILE BULB   penile bulb_P_P D0.1cc[Gy] <=10 29.5   Goal 1.807 Gy
NEUROVASCULAR BUNDLES   Neurovascular B1 D50.0%[Gy] <=37.5 40   Variation 37.550 Gy
RIGHT FEMORAL HEAD   Right Femoral H1 Max[Gy] <=10 27.5   Variation 10.124 Gy
LEFT FEMORAL HEAD   Left Femoral He1 Max[Gy] <=10 27.5   Variation 10.217 Gy
SKIN   Skin_P_P Max[Gy] <=10 30   Goal 7.994 Gy
TESTES   Testes_P_P Max[Gy] <=0 2   Variation 0.335 Gy
ScoreCard Metrics
Technical Plan Comments

This 10XFFF plan used 3 coplanar arcs and scored higher than all 6x/10x plans submitted to the competition. 

Comparative Plan Quality
Links

3rd party software plan report

PDF

 Dosimetric ScoreCard

JSON

DICOM patient export        

ZIP        

Any reference to a "plan study" are simply what the organizers call each case and may not be a "study" in the FDA sense as they may not have been published in a peer reviewed journal.
Varian does not provide medical advice and these are illustrative examples only.
Leading plans by expert planner. Your results may vary.

FOR EDUCATIONAL AND SCIENTIFIC EXCHANGE ONLY – NOT FOR SALES OR PROMOTIONAL USE.